Search results for "nickel titanium"

showing 10 items of 29 documents

An in vitro cyclic fatigue resistance comparison of conventional and new generation nickel-titanium rotary files

2018

Background New designs and processing of Niquel-Titanium (NiTi) have been introduced to increase resistance to cyclic fatigue. The purpose of this study was to compare the cyclic fatigue resistance of 3 NiTi rotary instruments, ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland), Profile Vortex Blue (PVB; Dentsply Tulsa Dental, Tulsa, OK, USA) and ProTaper Universal (PTU; Dentsply Maillefer, Ballaigues, Switzerland). Material and Methods A cyclic fatigue test was conducted operating instruments from ProTaper Next X2, Profile Vortex Blue 25.06 and ProTaper F2. A total of 234 instruments were rotated in 2 simulated stainless steel curved canals with different angles of curvature …

0301 basic medicine03 medical and health sciencesCyclic stress030104 developmental biology0302 clinical medicineMaterials scienceNickel titaniumManufacturing processUNESCO::CIENCIAS MÉDICAS030206 dentistryComposite material:CIENCIAS MÉDICAS [UNESCO]General DentistryJournal of Clinical and Experimental Dentistry
researchProduct

Quantitative and Qualitative in vivo Analysis of Metal Residuals in the Saliva of Subjects with and without Fixed Orthodontic Appliances

2020

Aim of the Work: The aim of this work was to evaluate Ni e Cr ions in the saliva of subjects with and without fixed orthodontic appliances. Materials and Methods: This was a prospective, non-randomized study of 100 patients, so selected: 50 have undergone fixed orthodontic appliance at least from 24 months; others 50 subjects as control-group, without any fixed and/or removable orthodontic appliance It was conducted according to the Declaration of the World Medical Association of Helsinki. The two selected groups were compatible for age, sex, absence of restoration in amalgam or other metals in the oral cavity. The saliva of all the subjects was collected with standardized sterile methods. …

0301 basic medicineSalivaMaterials scienceMetal ions in aqueous solutionfungiMetallurgytechnology industry and agriculture030206 dentistryGeneral MedicineBiocompatible materialCorrosionMetal03 medical and health sciences030104 developmental biology0302 clinical medicineNickel titaniumFixed Orthodontic Appliancevisual_artGalvanic cellvisual_art.visual_art_mediumNickel ionsAtomic Absorption SpectrophotometryMetal IonSaliva
researchProduct

The Effect of Taper and Apical Diameter on the Cyclic Fatigue Resistance of Rotary Endodontic Files Using an Experimental Electronic Device

2021

The aim of this study was to analyze the effect of the taper and apical diameter of nickel&ndash

Characteristic strengthinorganic chemicalsCyclic stressmedicine.medical_specialtyMaterials scienceapical diameterlcsh:TechnologyDynamic resistancelcsh:Chemistry03 medical and health sciences0302 clinical medicine0502 economics and businessEndodontic filesmedicineotorhinolaryngologic diseasesGeneral Materials SciencetaperInstrumentationlcsh:QH301-705.5endodontic rotary filesWeibull distributionFluid Flow and Transfer ProcessesOrthodonticsWeibull moduluslcsh:TProcess Chemistry and Technology05 social sciencesGeneral Engineering030206 dentistryEndodonticscyclic fatiguelcsh:QC1-999Computer Science Applicationsendodonticslcsh:Biology (General)lcsh:QD1-999Nickel titaniumlcsh:TA1-2040050211 marketingrotary movementlcsh:Engineering (General). Civil engineering (General)lcsh:PhysicsApplied Sciences
researchProduct

A comparative study of mechanical resistance of two reciprocating files

2019

Background To evaluate the cyclic fatigue resistance of two different Nickel-Titanium instruments, Reziflow (Komet, Brasseler GmbH & Co., Lemgo, Germany) and WaveOne Gold (Dentsply Maillefer, Ballaigues, Switzerland). Material and Methods Two groups of 20 different NiTi endodontic instruments of identical tip size of 0.25 mm were tested; Reziflow and Wave-One Gold primary. Cyclic fatigue testing was performed in a stainless steel simulated root canal manufactured by reproducing the instrument’s size and taper. A simulated root canal with a 90 degrees angle of curvature and 5 mm radius of curvature was constructed for the instruments tested. The centre of the curvature was 5 mm from the tip …

Cyclic stressMaterials scienceRoot canalNiTi alloyendodontic instruments02 engineering and technologyCurvatureOperative Dentistry and EndodonticsRadius of curvature (optics)03 medical and health sciencesReciprocating motion0302 clinical medicinemedicinecyclic fatigue; endodontic instruments; heat treatment; NiTi alloy; reciprocating motion; dentistry (all)reciprocating motionGeneral DentistryOrthodonticsdentistry (all)heat treatmentResearch030206 dentistryMechanical resistancecyclic fatigue021001 nanoscience & nanotechnology:CIENCIAS MÉDICAS [UNESCO]medicine.anatomical_structureNickel titaniumUNESCO::CIENCIAS MÉDICASFracture (geology)0210 nano-technology
researchProduct

Cutting efficiency of heat-treated nickel-titanium single-file systems at different incidence angles.

2020

Cutting efficiency of Reciproc R25 (REC) and Reciproc blue R25 (REB) at different inclinations was evaluated. Sixty new files were tested at 90°, 70° and 45° of inclination in relation to the sample (n = 10), using a customised machine. All files were activated in reciprocation against standardised gypsum blocks for 120 s. Cutting efficiency was determined by measuring the block weight loss with an analytical balance and measuring the length of the block surface cut using a digital calliper. Data were statistically analysed (two-way ANOVA, Bonferroni t-test) with the significance level set at P < 0.05. There was no difference for REC among the tested angles. REB had no statistical differenc…

Dental InstrumentsHot Temperatureincidence angle0206 medical engineeringStatistical differencecutting efficiency02 engineering and technology03 medical and health sciencesReciprocating motion0302 clinical medicineNickelStatisticsMaterials TestingGeneral DentistryIncidence (geometry)MathematicsTitaniumheat treatmentIncidenceSignificant difference030206 dentistryEquipment Designreciproc blue020601 biomedical engineeringNickel titaniumHeat treatedreciprocationCalipersRoot Canal PreparationAustralian endodontic journal : the journal of the Australian Society of Endodontology IncReferences
researchProduct

Shaping ability of nickel-titanium rotary instruments in simulated S-shaped root canals.

2009

Objective The aim of this study was to compare the shaping ability of 4 nickel-titanium rotary techniques and 1 hand technique in simulated S-shaped curved root canals. Study design Seventy-five simulated double-curved resin root canals were divided into 5 groups (n = 15). The canals were compared at 12 different levels and at 3 different times: before preparation and after preparation to master apical 25 and 35. Data were statistically analyzed by performing 2-by-2 comparisons with the Tukey parametric test of variance analysis using a confidence interval of 95%. Results All of the 75 resin blocks presented transportation of the root canals by transforming the apical curvature into a strai…

Dental Stress AnalysisDental InstrumentsFlexibility (anatomy)Hand techniqueRoot (chord)Normal DistributionDentistryCurvatureNickelmedicineHumansTooth RootPliabilityGeneral DentistryParametric statisticsMathematicsTitaniumAnalysis of Variancebusiness.industryStructural engineeringStainless SteelModels Dentalmedicine.anatomical_structureOtorhinolaryngologyNickel titaniumSurgeryEquipment FailureOral SurgeryDental Pulp CavitybusinessRoot Canal PreparationDental AlloysOral surgery, oral medicine, oral pathology, oral radiology, and endodontics
researchProduct

Load-deflection characteristics of superelastic and thermal nickel-titanium wires

2011

SUMMARY The aim of this study was to investigate the mechanical properties of superelastic and thermal nickel–titanium (NiTi) archwires for correct selection of orthodontic wires. Seven different NiTi wires of two different sizes (0.014 and 0.016 inches), commonly used during the alignment phase, were tested. A three-point bending test was carried out to evaluate the load–deflection characteristics. The archwires were subjected to bending at a constant temperature of 37°C and deflections of 2 and 4 mm. Analysis of variance showed that thermal NiTi wires exerted significantly lower working forces than superelastic wires of the same size in all experimental tests (P < 0.05). Wire size had a s…

Dental Stress AnalysisTitaniumHot TemperatureMaterials scienceOrthodontic wireMetallurgyBiomechanicschemistry.chemical_elementOrthodonticsElasticityLoad deflectionchemistryNickelNickel titaniumDeflection (engineering)MartensiteThermalOrthodontic WiresComposite materialDental AlloysMechanical PhenomenaTitaniumThe European Journal of Orthodontics
researchProduct

The efficacy of two rotary NiTi instruments and H-files to remove gutta-percha from root canals

2011

WOS: 000304343300026

K3 (R)Root canalDentistryNiTiEndodonticsNickelmedicineHumansStatistical analysisGeneral DentistryMathematicsR-Endo (R)TitaniumDental Pulp Cavitybiologybusiness.industryGutta-percha removalGutta-percha:CIENCIAS MÉDICAS [UNESCO]biology.organism_classificationmedicine.anatomical_structureOtorhinolaryngologyNickel titaniumUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgeryDental Pulp CavityGutta-PerchabusinessRoot Canal PreparationMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Mesenchymal stem cell proliferation and differentiation on load-bearing trabecular Nitinol scaffolds.

2013

Bone tissue regeneration in load-bearing regions of the body requires high-strength porous scaffolds capable of supporting angiogenesis and osteogenesis. 70% porous Nitinol (NiTi) scaffolds with a regular 3-D architecture resembling trabecular bone were produced from Ni foams using an original reactive vapor infiltration technique. The "trabecular Nitinol" scaffolds possessed a high compressive strength of 79 MPa and high permeability of 6.9×10(-6) cm2. The scaffolds were further modified to produce a near Ni-free surface layer and evaluated in terms of Ni ion release and human mesenchymal stem cell (hMSC) proliferation (AlamarBlue), differentiation (alkaline phosphatase activity, ALP) and …

Materials scienceAngiogenesisSurface PropertiesBiomedical EngineeringNeovascularization PhysiologicBone tissueBiochemistryLoad bearingBiomaterialsExtracellular matrixOsteogenesisMaterials TestingmedicineAlloysHumansMesenchymal stem cell proliferationMolecular BiologyCells CulturedCell ProliferationOsteoblastsTissue ScaffoldsGuided Tissue RegenerationMesenchymal stem cellEndothelial CellsCell DifferentiationMesenchymal Stem CellsGeneral MedicineEquipment DesignEquipment Failure Analysismedicine.anatomical_structureNickel titaniumBone SubstitutesAlkaline phosphataseBiotechnologyBiomedical engineeringActa biomaterialia
researchProduct

Shape memory NiTi thin films deposited at low temperature

1999

Abstract NiTi shape memory alloy (SMA) thin films have the potential to become high performance actuators for micro-electromechanical systems. Low temperature crystallized NiTi films would ensure a good compatibility with microelectronic processes and polymers. To avoid the drawbacks induced by annealing, we have tried to obtain low temperature crystallized RF sputtered NiTi films by optimising deposition parameters. We have found that NiTi films containing an excess of Ti (∼52%) were crystallized when deposited on Si(100) substrates heated up to only 473 K. NiTi/Si(n) Schottky diodes I–V characteristics showed a temperature dependence indicating structural transition in the NiTi electrode.…

Materials scienceAnnealing (metallurgy)Mechanical EngineeringSchottky effectMetallurgyTitanium alloyShape-memory alloyCondensed Matter PhysicsMechanics of MaterialsSputteringNickel titaniumDiffusionless transformationGeneral Materials ScienceThin filmComposite material
researchProduct